|
|
Rice Lake 211286 Deckhand DH1000 Legal for Trade Painted Steel with conductive wheel for use with 882IS 1000 lb - Base Only |
|
| The DeckHand portable scale is a mobile floor scale with an indicator platform. Partnered with one of Rice Lake’s battery-operated indicators, such as the 482 Plus Legend® series indicator, you will have a clearly visible weight anywhere the scale is located. If product is loaded off-center, all four corners of the platform weigh perfectly, so weight is measured accurately from anywhere on the platform. Take this scale to any work area for the immediate weight of large stationary items. more ... |
|
Industrial Scales >
Scale Bases No Indicator >
Scale Bases with Wheels
|
|
|
|
|
|
Features
The DeckHand portable scale is a mobile floor scale with an indicator platform. Partnered with one of Rice Lake’s battery-operated indicators, such as the 482 Plus Legend® series indicator, you will have a clearly visible weight anywhere the scale is located. If product is loaded off-center, all four corners of the platform weigh perfectly, so weight is measured accurately from anywhere on the platform. Take this scale to any work area for the immediate weight of large stationary items.
The DeckHand large rubber wheels simplify movement on uneven floors. The two wheels hover when stationary, so the weighing platform remains stable despite variances in floor contour. Environmentally sealed aluminum load cells help keep things lighter for easier mobility.
- Mild or stainless steel wheeled frame, base and mast
- Diamond tread top plate, mild or stainless steel
- Large rubber wheels (not rated for IS) simplify movement on uneven floors
- Two IP67 aluminum load cells
- Standard indicator mount with integral handles for the 380/380X Synergy, 480/480 Plus, 482/482 Plus, 880/880 Plus, 680 Synergy and 381 Synergy
|
|
Technical Specifications
Type
Mild Steel, with conductive wheel for use with 882IS
Pan Size
30.375 x 24 inch
Legal For Trade
NTEP Calss III #98-004 2,500 d; Measurement Canada #AM-5218
End Load Capacity
100% end loading
Cable length
9 ft 10 in (3 m)
Weighing Platter
4.5 in height when in weigh mode
Warranty
Weldment: Five-year - Load cells: Two- year - All other components: One- year
Options
Ramps, Smooth top, Mounting Bracket
|
|
|
Other Rice Lake Deckhand Base Only
|
Deckhand Base Only Specifications
| Model |
41293 DH500 |
41294 DH1000 |
41295 DH2000 |
211285 DH500 |
211286 DH1000 |
211287 DH2000 |
41296 DH500SS |
41297 DH1000SS |
41298 DH2000SS |
| Capacity |
500 lb |
1000 lb |
2000 lb |
500 lb |
1000 lb |
2000 lb |
500 lb |
1000 lb |
2000 lb |
| Type |
Mild Steel |
Mild Steel, with conductive wheel for use with 882IS |
Stainless Steel |
| Top Plate |
diamond-tread |
diamond-tread |
Smooth top |
| Pan Size |
30.375 x 24 inch |
| Legal For Trade |
NTEP Calss III #98-004 2,500 d Measurement Canada #AM-5218 |
| End Load Capacity |
100% end loading |
| Cable length |
9 ft 10 in (3 m) |
| mV/V Output |
2 mV/V |
| Weighing Platter |
4.5 in height when in weigh mode |
| Column Height |
59 in |
| Warranty |
Weldment: Five-year - Load cells: Two- year - All other components: One- year |
| Options |
Ramps, Smooth top, Mounting Bracket |
|
|
|
|
|
|
|
Optional Accessories
more info
|
Rice Lake 43376 500 - 1000 lb Ramp for DeckHand Rough-n-Ready 25 x 27 inch
Rice Lake 43376 500 - 1000 lb Ramp for DeckHand Rough-n-Ready 25 x 27 inch
|
|
more info
|
Rice Lake 882IS Intrinsically-Safe 185288 Digital Weight Indicator with Battery Pack Charger & tilt Stand
The Hazardous Environment Instrumentation Solution
Designed for hazardous locations that are potentially explosive, the 882IS digital weight indicator is built to safely operate in these settings without sacrificing performance. With cFMus, ATEX and IECEx approvals, the 882IS is the industry’s choice for flammable and combustible applications such as fuel refineries, chemical plants, distilleries, textile manufacturing and more.
Safe, Accurate Weight Readings in Hazardous Locations
The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications.
The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.
Enhanced Connectivity
Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module.
To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator
FEATURES
- Seven-digit, seven-segment LCD display with white LED backlight
- Stainless steel NEMA IP66 enclosure
- T4 temperature rating
- Front panel digital calibration
- Numeric keypad (882IS Plus only)
- Duplex fiber optic interface
- Power ON/OFF; battery save mode
- I/O module option: one serial port, optional analog outputs, optional fieldbus cards
- FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file numbers 180948, 182301, and 186430
OPTIONS
- Battery option, IS6V2 VDC
- Battery charger, 6 VDC
- Power supply, 882IS mb-EPS-100-240-X2, dual output 6.8 VDC 200mA
- Cable, M12 power 22 in hazardous location (for battery version)
- Cable, M12 power 10 ft hazardous location
- Cable, M12 power 50 ft hazardous location
- Cable, M12 power 100 ft hazardous location
- Tilt stand, 882IS battery option
- Module, 882 smart I/O interface
882IS/882IS Plus Hazardous (Classified) Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
| Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEX FMG 18.0018X |
| Approval Standards |
FM/cFM: INTRINSICALLY SAFE Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
| Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIC T135°C Da |
Model IS6V2 (Battery) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
| Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
| Approval Standards |
FM/cFM: INTRINSICALLY SAFE IS for Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
| Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II1 D Ex ia IIIC T135°C Da |
Model IS6V2 (Battery) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
| Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
| Approval Standards |
FM/cFM: INTRINSICALLY SAFE IS for Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
| Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II1 D Ex ia IIIC T135°C Da |
Model mb-EPS-100-240-X2 (Power Supply) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and ICEx Requirements
| Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
| Approval Standards |
FM/cFM: Class I,II,III, Division 1, Groups ABCDEFG T4 with IS outputs for Class I,II,III, Division 1, ABCDEFG Class I, Zone 1, AEx/Ex mb [ia Ga] IIC T4 Gb Zone 21, AEx/Ex mb [ia Da] IIIC T135°C Db Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
| Equipment Ratings |
II 2(1) G Ex mb [ia Ga] IIC T4 Gb II 2(1) D Ex mb [ia Da] IIIC T135°C Db |
|
|
more info
|
Rice Lake Deckhand Mounting Bracket ASSY, IQ700IS, 320IS With Battery And 882IS With Battery To Deckhand Mast, SST construction
Rice Lake Deckhand Mounting Bracket ASSY, IQ700IS, 320IS With Battery And 882IS With Battery To Deckhand Mast, SST construction
|
|
|
|
|
|
|
|
|