Rice Lake 882IS Intrinsically-Safe 194235 Digital Weight Indicator A/C Power Supply Tilt Stand and Metric Thread Adapter (1/2NPT - M20) |
|
Designed for hazardous locations that are potentially explosive, the 882IS digital weight indicator is built to safely operate in these settings without sacrificing performance. With cFMus, ATEX and IECEx approvals, the 882IS is the industry’s choice for flammable and combustible applications such as fuel refineries, chemical plants, distilleries, textile manufacturing and more more ... |
Scales >
Indicators & Remote Displays >
Indicators & Remote Displays
|
|
|
|
Features
The Hazardous Environment Instrumentation Solution
Designed for hazardous locations that are potentially explosive, the 882IS digital weight indicator is built to safely operate in these settings without sacrificing performance. With cFMus, ATEX and IECEx approvals, the 882IS is the industry’s choice for flammable and combustible applications such as fuel refineries, chemical plants, distilleries, textile manufacturing and more.
Safe, Accurate Weight Readings in Hazardous Locations
The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications.
The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.
Enhanced Connectivity
Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module.
To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator
FEATURES
- Seven-digit, seven-segment LCD display with white LED backlight
- Stainless steel NEMA IP66 enclosure
- T4 temperature rating
- Front panel digital calibration
- Numeric keypad (882IS Plus only)
- Duplex fiber optic interface
- Power ON/OFF; battery save mode
- I/O module option: one serial port, optional analog outputs, optional fieldbus cards
- FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file numbers 180948, 182301, and 186430
OPTIONS
- Battery option, IS6V2 VDC
- Battery charger, 6 VDC
- Power supply, 882IS mb-EPS-100-240-X2, dual output 6.8 VDC 200mA
- Cable, M12 power 22 in hazardous location (for battery version)
- Cable, M12 power 10 ft hazardous location
- Cable, M12 power 50 ft hazardous location
- Cable, M12 power 100 ft hazardous location
- Tilt stand, 882IS battery option
- Module, 882 smart I/O interface
882IS/882IS Plus Hazardous (Classified) Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEX FMG 18.0018X |
Approval Standards |
FM/cFM: INTRINSICALLY SAFE Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIC T135°C Da |
Model IS6V2 (Battery) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
Approval Standards |
FM/cFM: INTRINSICALLY SAFE IS for Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II1 D Ex ia IIIC T135°C Da |
Model IS6V2 (Battery) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and IECEx Requirements
Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
Approval Standards |
FM/cFM: INTRINSICALLY SAFE IS for Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 20 AEx/Ex ia IIIC T135°C Da Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
Equipment Ratings |
II 1 G Ex ia IIC T4 Ga II1 D Ex ia IIIC T135°C Da |
Model mb-EPS-100-240-X2 (Power Supply) Hazardous Location Electrical Equipment Per U.S., Canadian, ATEX and ICEx Requirements
Certificate No: |
FM18US0195X, FM18CA0092X, FM18ATEX0047X, IECEx FMG 18.0018X |
Approval Standards |
FM/cFM: Class I,II,III, Division 1, Groups ABCDEFG T4 with IS outputs for Class I,II,III, Division 1, ABCDEFG Class I, Zone 1, AEx/Ex mb [ia Ga] IIC T4 Gb Zone 21, AEx/Ex mb [ia Da] IIIC T135°C Db Ta = -10°C to +40°C (14°F to 104°F) ATEX/IECEx |
Equipment Ratings |
II 2(1) G Ex mb [ia Ga] IIC T4 Gb II 2(1) D Ex mb [ia Da] IIIC T135°C Db |
Weight:
7.00 lb
|
1 Year Manufacture Warranty
|
Other Rice Lake 882IS Intrinsically-Safe Indicators
|
Specifications
Model |
882IS |
882IS Plus |
185288 |
194235 |
195091 |
185291 |
185293 |
195092 |
Battery pack, Charger & Tilt Stand |
Included |
- |
- |
Included |
- |
- |
A/C power supply |
- |
Included |
- |
- |
Included |
- |
Front Panel Control Switches |
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop |
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad |
Front Panel |
Ten-button plus power button flat membrane panel |
Ten-button plus power button flat membrane panel and full numric keys |
Front Panel LED Annunciators |
Center Zero, Gross, Net, Motion, lb, kg, oz, g |
Legal For Trade |
NTEP CC 19-015 Class III/IIIL 10,000d Measurement Canada AM-6124C |
Factory Mutual |
FM entity approved for classes I, II, and III; Divisions 1 and 2; Groups A, B, C, D, E, F, and G |
Load Cell Excitation: |
3.0 VDC at 87.5 O 4.6 VDC at 700 O |
Load Cell Current |
34 mA (4 x 350 &Omega load cells) or (8 x 700 &Omega load cells) |
Load Cell Cabling |
4 and 6-wire with remote sensing (recommended) |
Analog Signal Input Range |
0.6 mV/V - 4.0 mV/V |
Analog Signal Sensitivity |
0.2 µV/graduation minimum 1.5 µV/graduation recommended |
Conversion Rate |
60 updates/second |
Resolution |
10,000 displayed graduations (NTEP Certified),100,000 expanded
The maximum number of allowed graduations will vary by application Display Increments: |
Display Increments |
1, 2, 5 |
Decimal Point |
Configurable with dead zeros |
Unit Switching |
Configurable for 2 units of measurement with front panel operation with conversion for tare and setpoint values |
Motion Band |
Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off) |
Power Input |
5.8 - 7.9 VDC,100 - 175 mA Maximum power consumption 0.25 watts |
Operating Temperature |
14° F to 104° F (-10° C to 40° C) legal for trade |
Rating/Material |
Stainless steel NEMA Type 4X/IP66 enclosure |
Optional Battery |
Operating times: 4 x 350 O = 60 hrs
1 x 350 O =80-100 hrs
Charging Times: 8-10 hrs for dead battery |
Weight |
6.1 lb (2.8 kg) |
Warranty |
One-year limited warranty |
Approvals |
NTEP CC 19-015 Class III/IIIL 10,000d
c-UL Listed
FM Entity
Measurement Canada |
|
|
|
|
Optional Accessories
more info
|
Rice Lake 78027 Fiber optic, duplex cable 200 ft for 320IS, CW-90 and CW90X, 882IS
Rice Lake 78027 Fiber optic, duplex cable 200 ft for 320IS, CW-90 and CW90X
|
|
more info
|
Rice Lake 177709 882 Smart I/O Interface for 882IS Smart Card Interface, Ethernet Fiber-Optic/RS485 Interface Module
Rice Lake 177709 882 Smart I/O Interface for 882IS Smart Card Interface, Ethernet Fiber-Optic/RS485 Interface Module
|
|
more info
|
Rice Lake 163751 880 Desktop Indicator Stand
Rice Lake 163751 880 Desktop Indicator Stand
|
|
more info
|
Rice Lake 179671 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (100 ft)
Rice Lake 179671 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (100 ft)
|
|
more info
|
Rice Lake 179670 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (50 ft)
Rice Lake 179670 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (50 ft)
|
|
more info
|
Rice Lake 179669 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (10 ft)
Rice Lake 179668 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (22 in)
|
|
more info
|
Rice Lake 179668 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (22 in)
Rice Lake 179668 M12 Hazardous Location D-Code Straight Male to Right Angle Female Cable (22 in)
|
|
more info
|
Rice Lake 195109 Dual Output 6.8VDC 200mA 882IS mb-EPS-100-240-X2 Power Supply [thread adapter included 1/2in NPT - M20]
Rice Lake 195109 Dual Output 6.8VDC 200mA 882IS mb-EPS-100-240-X2 Power Supply [thread adapter included 1/2in NPT - M20]
|
|
more info
|
Rice Lake 180837 Dual Output 6.8VDC 200mA 882IS mb-EPS-100-240-X2 Power Supply
Rice Lake 180837 Dual Output 6.8VDC 200mA 882IS mb-EPS-100-240-X2 Power Supply
|
|
more info
|
Rice Lake 194192 IS6V2 100-240Vac BS1363 Battery Charger (UK Molded Plug)
Rice Lake 194192 IS6V2 100-240Vac BS1363 Battery Charger (UK Molded Plug
|
|
more info
|
Rice Lake 194189 IS6V2 100-240VAC CEE 7/7 Battery Charger (Continental Europe Plug)
Rice Lake 194189 IS6V2 100-240VAC CEE 7/7 Battery Charger (Continental Europe Plug)
|
|
more info
|
Rice Lake 194191 IS6V2 100-240VAC NEMA 5-15 Battery Charger (North America Plug)
Rice Lake 194191 IS6V2 100-240VAC NEMA 5-15 Battery Charger (North America Plug)
|
|
more info
|
Rice Lake 180831 Rechargeable IS6V2 Barrier Protected Battery Option
Rice Lake 180831 Rechargeable IS6V2 Barrier Protected Battery Option
|
|
more info
|
Rice Lake 78026 Fiber optic, duplex cable 100 ft for 320IS, CW-90 and CW90X, 882IS
Rice Lake 78026 Fiber optic, duplex cable 100 ft for 320IS, CW-90 and CW90X
|
|
more info
|
Rice Lake 190528 882 Single Analog Output (0-10VDC, 0-20mA, 4-20mA)
Rice Lake 190528 882 Single Analog Output (0-10VDC, 0-20mA, 4-20mA)
|
|
more info
|
Rice Lake 190530 882 Ethernet/IP CompactCom Option
Rice Lake 190530 882 Ethernet/IP CompactCom Option
|
|
more info
|
Rice Lake 190531 882 DeviceNet CompactCom Option
Rice Lake 190531 882 DeviceNet CompactCom Option
|
|
more info
|
Rice Lake 190532 882 ProfiNet Option
Rice Lake 190532 882 ProfiNet Option
|
|
more info
|
Rice Lake 190534 882 Profibus CompactCom Option
Rice Lake 190534 882 Profibus CompactCom Option
|
|
more info
|
Rice Lake 190533 882 Modbus TCP CompactCom Option
Rice Lake 190533 882 Modbus TCP CompactCom Option
|
|
more info
|
Rice Lake 190535 882 EtherCAT CompactCom Option
Rice Lake 190535 882 EtherCAT CompactCom Option
|
|
|
|
|
|
|