Mettler Toledo 30997809 Spectrophotometer Easy UV ScanStart |
|
| Easy UV and Easy VIS instruments both offer 3-in-1 functionality and are designed to greatly facilitate routine spectroscopic workflows. The instruments are simple and easy-to-use and assure accurate, repeatable measurements. Built-in methods also eliminate calculation and transcription errors. These versatile instruments help you more ... |
|
Laboratory Equipment >
Spectrophotometers >
Spectrophotometers
|
Note: This product can only be shipped Ground Delivery.
|
|
|
|
|
|
|
|
Features
Easy UV and Easy VIS instruments both offer 3-in-1 functionality and are designed to greatly facilitate routine spectroscopic workflows. The instruments are simple and easy-to-use and assure accurate, repeatable measurements. Built-in methods also eliminate calculation and transcription errors. These versatile instruments help you
- Enjoy fast, compliant color measurement. Includes 30 color scales (e.g. CIELAB, APHA, Gardner, etc.).
- Avoid errors. PathDetect™ securely checks the path length so your results are accurate.
- Fast and flexible water testing: The SQKitReader™ accessory provides access to over 150 Spectroquant® water test kit methods. ScanStart™ bundles, including a barcode scanner, are the flexible solution for using NANOCOLOR® test kits.
- Access methods easily. Built-in features such as a favorite list and LongClick™ speed up routine analyses.
- Clean up quickly thanks to a washable drip tray.
- Measurement versatility - Conventional spectrophotometry, color measurements, and water analyses can be performed using one instrument. This saves bench space and reduces your investment in equipment and service. Exchangeable XPathHolders™ allow you to shift quickly between seven different path lengths to suit a wide application and concentration range.
- Efficient accuracy - Photometric data is automatically calculated using pre-programmed methods so you obtain results quickly (e.g. concentration or tristimulus values). Methods that are compliant to standards such as ASTM, DIN, ISO, and EPA eliminate the need for post-measurement calculation and data transcription to achieve accurate results efficiently
- Data management - Data acquisition, storage, and display are efficiently performed by EasyDirect™ UV/VIS PC software. Result data can also be automatically exported to a memory stick or integrated into an external centralized data management system (e.g. LIMS)
- Verified, up-to-date methods - Software updates, competent application support, and verified methods allow you to update the instrument to support new analytical needs. EasyDirect™ customers receive an automated notification when a new update is available for download.
- Intuitive operation - The intuitive user interface with workflow guidance and integrated tutorials allow you to simply plug-and-measure. Additional functions such as closing the SmartLid™ to automatically start the measurement, increase productivity, and avoid time-consuming task repetition.
|
|
Other Mettler Toledo Spectrophotometer Easy
|
Specifications
| Model |
UV/Vis 30997809 |
Vis 30997810 |
| Light source |
Xenon flash lamp |
Tungsten lamp |
| Detector |
Dual silicon photodiodes |
| Optical system |
Dual beam with reference detector |
| Spectral bandwidth (SBW) [nm] |
3 |
4 |
| Photometric display range [A] |
–3.0 ... +5.0 |
| Photometric accuracy [A] |
at 0.5 A |
+ 0.002 |
| at 1.0 A |
+ 0.005 |
| at 2.0 A |
+ 0.005 |
| at 2.5 A |
+ 0.010 |
| Photometric repeatability at 1 A (neutral density filter) [A] |
< 0.001 |
| Wavelength range [nm] |
190–1,000 |
330–1,000 |
| Wavelength accuracy (holmium oxide) [nm] |
+ 1.5 |
| Wavelength repeatability (holmium oxide) [nm] |
< 0.5 |
| Stray light [%T] |
at 340 nm (sodium nitrite) |
< 0.1 |
< 0.1 |
| at 220 nm (sodium iodide) |
< 0.5 |
- |
| at 198 nm (potassium chloride) |
< 2.5 |
- |
| Scanning speed [nm/min] |
max 2,000 |
max 2,800 |
| Noise [A] |
at 0 A |
< 0.001 |
| at 1 A |
< 0.002 |
| at 2 A |
< 0.004 |
| Drift [A/h] |
< 0.002 |
| Baseline flatness [A] |
+ 0.003 |
| Applications and methods |
Max. user-defined methods |
80 |
| Built-in color scales (e.g. CIELAB) |
30 |
25 |
| NANOCOLOR® 1) water testing methods |
Free and available on METTLER TOLEDO website |
| Spectroquant® 2) water testing methods |
Covers all test kits (>150 methods) |
| NuNumber of user-defined methods in favorite list |
10 |
| Firmware and method upgrade |
Free and available on METTLER TOLEDO website |
| Automatic path length detection |
Enabled |
| PC software |
EasyDirect™ UV/VIS |
| Result |
Automatic export to USB (.csv file) |
Enabled |
| Automatic export to EasyDirect (.xml file) |
Enabled |
| Cuvette dimensions supported by the XPathHolders™ |
10, 16, 20, 30, 40, 50 mm and 1 inch |
| Display |
4.3" capacitive touchscreen |
| Connectivity |
USB-A |
× 3 (keyboard, mouse, barcode reader, printer) |
| USB-B |
× 1 (EasyDirect™ PC software) |
| Pogo Pin |
× 1 (SQKitReader™ for water testing methods) |
| Languages |
Bahasa Indonesia, Chinese, English, French, German, Italian, Japanese, Korean, Polish, Portuguese, Spanish, Thai, Turkish |
| Dimensions (width × depth × height mm) |
201 × 362 × 176 (7.9 × 14.2 × 6.9 inches) |
| Weight (kg) |
4.25 |
| Power requirements |
AC to DC converter included, 100–240 V, 50–60 Hz |
|
|
|
|
* within the 48 continental US States
|
|
Optional Accessories
more info
|
Mettler Toledo 51191926 USB Cable (1.8 m A-B) for PC or printer
USB extension cable, 1.8 m.
|
|
more info
|
Mettler Toledo 30702998 Lab equip acc data writer USB-P25/00
Dot matrix printer, USB interface, print speed 2.3 lines per second, auto settings detection
Fast and Reliable Whether you deal with simple or sophisticated applications, the printer generates fast and clear copies of your results.
Statistical & Totaling Applications Print in the language in which your connected Mettler-Toledo instrument is operating.
USB Interface The USB-25 printer has a USB interface which makes connection to your instrument quick and easy.
|
|
more info
|
Mettler Toledo 30705183 Internal Barcode Reader Set SQKitReader
The SQKitReader™ option enables your EasyPlus UV/VIS spectrophotometer to read the 2D barcode of Spectroquant® water test kits.
|
|
more info
|
Mettler Toledo 30657871 License EasyDirect UV/VIS 1 Instrument
Data acquisition, storage, and display are efficiently performed by EasyDirect™ UV/VIS PC software.
|
|
more info
|
Mettler Toledo 30705122 Cuvette Carousel XPathHolder 10/16mm
Enhance your analysis capabilities and simplify testing workflows with this cuvette carousel. Designed for compatibility with 10 mm cuvettes and 16 mm outer diameter glass tubes, it includes a secure cuvette holder for reliable positioning. For optimal performance, only one carousel can be installed in the analysis compartment at a time.
|
|
more info
|
Mettler Toledo 30705123 Cuvette Carousel XPath Holder 20mm/30mm
Enhance your analysis capabilities and simplify testing workflows with this cuvette carousel. Designed for compatibility with 10 mm cuvettes and 16 mm outer diameter glass tubes, it includes a secure cuvette holder for reliable positioning. For optimal performance, only one carousel can be installed in the analysis compartment at a time.
|
|
more info
|
Mettler Toledo 30705124 Cuvette Carousel XPath Holder 40/50mm/1 inch
Enhance your analytical flexibility with the Mettler Toledo 30705124 Cuvette Carousel XPath Holder. Designed to accommodate 40 mm, 50 mm, and 1-inch path length cuvettes, this holder enables precise positioning for consistent and reliable measurements. Ideal for expanding testing capabilities while maintaining accuracy. Note: only one carousel can be installed in the analysis compartment at a time.
|
|
more info
|
Mettler Toledo 30675053 Cuvette Standard O Optical Glass 10 mm
The Standard O macro cuvette with an optical path length of 10 millimeters is made of fritted optical glass and comes in a matching pair. For measurements in the visible range with a wavelength between 320 nm – 2500 nm.
|
|
more info
|
Mettler Toledo 30675054 Cuvette Standard O Optical Glass 50 mm
The Standard Line O macro cuvette with an optical path length of 50 millimeters is made of fritted optical glass and comes in a matching pair. For measurements in the visible range with a wavelength between 320 nm – 2500 nm.
|
|
more info
|
Mettler Toledo 30675051 Cuvette Standard Q Quartz Glass 10 mm
The Standard O macro cuvette with an optical path length of 10 millimeters is made of fritted optical glass and comes in a matching pair. For measurements in the visible range with a wavelength between 320 nm – 2500 nm.
|
|
more info
|
Mettler Toledo 30675052 Cuvette Standard Q Quartz Glass 50 mm
The Standard Q macro cuvette with an optical path length of 50 millimeters is made of fused quartz glass and comes in a matching pair. For measurements in the ultraviolet and visible range with a wavelength between 200 nm – 2500 nm.
|
|
more info
|
Mettler Toledo 30705156 Drip Tray EasyPlus UV/VIS
Protect your instrument and maintain a clean workspace with the Mettler Toledo 30705156 Drip Tray for EasyPlus UV/VIS spectrophotometers. Designed to catch spills and drips during sample handling, this accessory helps prevent contamination and simplifies cleanup, ensuring reliable operation and extended instrument life.
|
|
|
|
|
|
|
|
|