Model |
7820 AWT05-508638 |
7820 AWT05-508639 |
7820 AWT05-508640 |
7820 AWT05-508641 |
7820R AWT05-508642 |
7820R AWT05-508643 |
Capacity x Readability |
100 lb x 0.02 lb |
100 lb x 0.02 lb |
150 lb x 0.05 lb |
150 lb x 0.05 lb |
150 lb x 0.05 lb |
150 lb x 0.05 lb |
50 kg x 0.01 kg |
50 kg x 0.01 kg |
60 kg x 0.02 kg |
60 kg x 0.02 kg |
60 kg x 0.02 kg |
60 kg x 0.02 kg |
Legal For Trade |
NTEP approved for use in Class III operations, CC 95-070 |
Canada Weights and Measures approval CC # AM-5076 Rev 4 |
Computer Interface |
1 x RS232 (9 way female D Type connector ), 1 x USB HID (Mini USB) or 1x USB VCP (USB-Type B)
1 x 2nd Remote display connection (RJ 45) All are positioned on the rear of the base |
Platter Type |
Stainless steel weight platter |
Stainless Steel Ball Top (9 balls) |
Stainless steel weight platter |
Stainless Steel Ball Top (9 balls) |
Stainless steel weight platter |
Stainless Steel Ball Top (9 balls) |
Display Type |
Flush fitting six digit, ½” high LCD display |
Remote six digit, ½” high digit LCD display housed in an extruded enclosure with a 7 foot cable Optional 2nd remote (for the 7815 only ) Six digit ½” high LCD display housed in an extruded enclosure with a 7 foot cable, connected via RJ 45 connector on the rear of the scales base |
Number of Displays Allowed |
2 (1 standard, 1 remote display optional) |
1 remote display |
Platter Size |
12" x 14" |
12" x 14" |
12" x 14" |
12" x 14" |
12" x 14" |
12" x 14" |
Base Construction |
Rugged with powder coated die cast aluminum housing and load bridge, housing a aluminum NTEP approved analog load cell
Lockable adjustable feet, 1” diameter with up to 1” of height adjustment |
Power |
120 VAC (+10% -15%), 60 Hz, standard 3-wire ground |
Operating Environment |
Temperature: 42° F to 104° F (5° C to 40° C) Relative Humidity: 10 to 95% (non-condensing) |
Remote Display Housing Sizes |
8” x 3” x 1.5” |
Operational Keyss |
ZERO: Includes Auto Zero Tracking or Manual push button to re-establish zero reference TEST: Runs a diagnostic test to ensure scale is fully functional and allows a real-time view of internal settings |
Units of Measure |
lb or kg (lb default)” |
Configurable Selections |
Capacity, resolution, filters, baud rates, protocols, auto printout, scale or post classifier Default configuration is as postal weight classifier |
Incremental Selections |
Multiples and sub-multiples of 1, 2, 5 |
Calibration |
2 point calibration process (zero and span capacity) Field calibration can be carried out by using less than full capacity weights Gravity compensation to allow the local gravity to be entered for where the scale is to be used |
Internal Resolution |
1 part in 120,000 |
Self-Diagnostics |
2 level diagnostics: front panel display test or full service diagnostics. (Display, RAM, ROM, input/output & high
resolution x10 division test) |