Features
The Chatillon DFS-R-ND Series force gauges supply accurate load and torque measurement in a common gauge. Ideal for hand held or test stand applications, the DFS-R-ND gauge may be equipped with smart loadcells or torque sensors. The auto-recognition feature knows whether a load or torque measurement is required. Measurement accuracy is better than 0.25% full scale when used with interchangeable sensors. Accuracy is better than 0.1% full scale when specified with a dedicated SCL load sensor.
A large, easy to read, high resolution dot matrix LCD display supports a variety of standard gauge functions, including normal and peak readings, high / low limits, setpoints, pass / fail results, statistical results, load averaging, load comparisons, percentage and sharp break detection, sensor actuation and direction. Measurements are displayed in ounce, gram, pound, kilogram or Newton units or in oz-in, g-cm, lb-in, N-cm and N-m units.
The Chatillon DFS-R-ND force gauge comes standard with an RS-232 cable, carrying case, battery adapter / charger, and NIST Certificate of Calibration with data.
Features:
- Dedicated or interchangeable sensors
- Load and torque sensors
- Accuracies to better than 0.1% full scale
- Advanced Operating Modes
- Normal
- Peak tension, compression and torque
- Percentage or sharp break detection
- Load comparisons and load averaging
- Contact closure
- Load limits
- Pass-fail limits
- Statistical Calculations
- Mean with maximum and minimum values
- Coefficient of variation with mean and standard deviation
- Standard deviation with variance and mean
- Percent differentiation
- Simple Operator Interface
- High resolution dot matrix display
- Menus with prompts for easy use
- Dedicated and function keys with navigation pod
- Standard Outputs - RS-232 serial data, Mitutoyo Digimatic, ±2Vdc Analog
- NIST Calibration with Data - available IEC/ISO17025 cert with uncertainty
- 2 year warranty
Model |
Remote Sensors for Load Measurement |
ounce |
gram |
pound |
kilogram |
Newton |
SLC-250G |
9 x 0.002 |
250 x 0.05 |
0.55 x 0.0001 |
- |
2.5 x 0.0005 |
SLC-0002 |
35 x 0.01 |
1000 x 0.2 |
2.2 x 0.0005 |
1 x 0.0002 |
10 x 0.002 |
SLC-0010 |
180 x 0.05 |
5000 x 1 |
11 x 0.002 |
5 x 0.001 |
50 x 0.01 |
SLC-0025 |
350 x 0.1 |
10000 x 2 |
22 x 0.005 |
10 x 0.002 |
100 x 0.02 |
SLC-0050 |
900 x 0.2 |
25000 x 5 |
50 x 0.01 |
25 x 0.005 |
250 x 0.05 |
SLC-0100 |
1800 x 0.8 |
50000 x 10 |
100 x 0.02 |
50 x 0.01 |
500 x 0.1 |
SLC-0200 |
3500 x 1 |
- |
220 x 0.05 |
100 x 0.02 |
1000 x 0.2 |
SLC-0500 |
- |
- |
560 x 0.1 |
250 x 0.05 |
2500 x 0.5 |
SLC-1000 |
- |
- |
1100 x 0.2 |
500 x 0.1 |
5000 x 1 |
SLC-2000 |
- |
- |
2000 x 0.2 |
1000 x 0.1 |
10000 x 1 |
SLC-5000 |
- |
- |
5000 x 0.5 |
2500 x 0.2 |
25000 x 2 |
SLC-10000 |
- |
- |
10000 x 1 |
5000 x 0.5 |
50000 x 5 |
|
Remote Sensors for Torque Measurement |
STS-0003 |
50 x 0.01 |
3600 x 0.5 |
3 x 0.0005 |
3.6 x 0.0005 |
0.35 x 0.0005 |
STS-0012 |
192 x 0.05 |
13830 x 3 |
12 x 0.002 |
13.9 x 0.003 |
1.36 x 0.0003 |
STS-0050 |
800 x 0.2 |
57600 x 10 |
50 x 0.01 |
57.6 x 0.01 |
5.7 x 0.001 |
STS-0100 |
1600 x 0.3 |
- |
100 x 0.02 |
115.2 x 0.02 |
11.3 x 0.002 |
STS-0200 |
3200 x 0.5 |
- |
200 x 0.04 |
230.4 x 0.05 |
22.6 x 0.005 |
Specifications
- Accuracy: ±0.1% of full scale (dedicated SLC sensor) ±0.25% of full scale (interchangeable SLC or STS sensors)
- Certification: calibration with NIST data, IEC/ISO17025 optional
- Data Sampling Rate: 5000 Hz
- Peak Capture Rate: 5000 Hz
- Display Update Rate: 10 Hz
- Tare Capacity: 10% full scale
- Overload Protection: 150% full scale
- Display Characteristics: high resolution, dot matrix LCD, 8 lines, 40 characters, adjustable contrast, invert and hide capability
- Automatic Shut Down: configurable time. May be disabled.
|
- Data Storage: 10 results, optional NEXYGEN software for unlimited storage and automated testing and analysis.
- Test Stand Control: Compatible with Chatillon TCD series test stands and Chatillon TCM series test stands
- Outputs: RS-232, Mitutoyo (Digimatic) and ±2Vdc analog
- Power: Battery or direct AC operation. Universal Power: 120V / 230V, Rechargeable nickel metal hydride (supplied)
- Battery Life: 30 hours, continuous use. Gauge may be operated with direct AC power source
- Instrument Weight: 1.5 lbs
- Operating Temperature: 40 to 100 F (4 to 38 C)
- Warranty: 2 years
|
SLC Loadcells and STS Torque Sensors
SLC Series Loadcells for DFS-R-ND Gauges:
The Chatillon SLC series loadcells are full-bridge strain gauge sensors complete with 15-pin plug. These loadcells are used exclusively with the Chatillon DFS-R-ND series gauges. The loadcell values and sensitivity factors are stored in memory within the sensor plug. When connected to a DFS-R-ND gauge, the capacity and calibration points are automatically recognized by the instrument. The instrument then becomes a full-featured load measurement instrument. The SLC loadcells meet ASTM E4 and BS EN ISO 7500 part 1 for a ±0.25% accuracy sensor. The loadcells are connected to the DFS-R-ND gauge with a retractable cord that extends fully to nearly 9 feet (3 meters). |
STS Series Torque Sensors for DFS-R-ND Gauges:
The Chatillon STS series torque sensors are full bridge strain gauge sensors complete with 15 pin plug. These sensors are used exclusively with the Chatillon DFS-R-ND gauge. The sensors torque values and sensitivity factors are stored in memory within the sensor plug. When connected to a DFS-R-ND indicator, the capacity and calibration points are automatically recognized by the instrument. The instrument then becomes a full-featured torque measurement instrument. The STS series torque sensor meet ASTM E4 and BS EN ISO 7500 part 1 for a ±0.25% accuracy sensor. The sensors are connected to the DFS-R-ND gauge with a retractable cord that extends fully to nearly 9 feet (3 meters). |
Weight:
10.00 lb
|
|