Ohaus FC5513 Frontier 5000 Micro Series Benchtop Centrifuge, 120V, 24 x 1.5 / 2.0 ml, 200 rpm – 13,500 rpm |
|
Frontier Micro centrifuges deliver high-speed operation for a range of essential lab applications, such as DNA/RNA preparation, ultrafiltration, and more. Biocontainment rotors enable research involving hazardous samples. Engineered with convenience of operation in mind, these centrifuges feature an intuitive interface, with all key parameters immediately accessible for observation and adjustment. The compact design saves valuable bench space in the lab. more ... |
Laboratory Equipment >
Centrifuges >
Centrifuges
|
|
|
|
Features
Compact Micro Centrifuges with Modern Touch-Wheel Interface Ideal for High-Speed Lab Applications
Frontier 5513 & 5513R Benchtop Micro Centrifuges as high speed centrifuges are capable of generating approx 17,000 x g. With refrigeration capabilities (FC5513R), seven optional rotors are designed for a range of essential lab applications. Engineered with convenient operation in mind, Frontier 5513 & 5513R feature a uniquely designed splash-proof front panel with touch-wheel control on an intuitive interface. The compact design saves valuable bench space in the lab.
Unique Features:
- Frontier 5513 & 5513R offer standard 24 x 1.5/2 ml microtube rotors with a biosealed option. The centrifuges can also support spin columns and hematocrit capillary tubes when used with additional rotor options.
- Designed for ease of operation, the FC5513 & FC5513R features convenient control on a protective splash-proof interface, which allows for responsive operation—even when wearing gloves.
- With a small footprint, Frontier 5513 & 5513R centrifuges are compact enough to save valuable space on the bench, yet large enough to accommodate the most common size 24 x 1.5/2.0 ml rotors.
Sleekly designed interface enables smooth operation for a great user experience
- Easy-to-Use touch-wheel interface for parameter adjustments
- Convenient interface shows both set and actual parameters
- One-touch toggling between RPM/RCF, Acc/Dec
- Crisp display on a double-line LCD display with backlight
Solid engineering to ensure functionality and reliability
- True splash-proof panel protects the centrifuge from accidental sample spilling
- Maintenance-free induction motor produces maximum G-force of 17,317 x g for FC5513 and 17,157 x g for FC5513R
- Speeds up to 13,500 rpm in less than 15 seconds with 24 x 1.5/2.0 ml rotor
- 10 acceleration/deceleration settings
- 99 memory sets to quickly store and recall commonly used parameters
- FC5513R model has refrigeration capabilities from 40°C to -20°C
- Pre-cool feature in FC5513R quickly lowers the temperature of rotor and chamber before a run
Flexible rotor selections to cover essential laboratory applications
- Works with microtube rotors with different rotor capacity - 18 x 1.5/2.0 ml or 24 x 1.5/2.0 ml
- Compatible with up to 7 rotor option and maximum rotor capacity of 24 x 1.5/2.0 ml
- Support spin-column and hematocrit capillary tubes through additional rotor options
Safety features that prevent injury
- Biosealed rotor is available for safe handling of hazardous samples
- Rotor imbalance sensing systems stops the unit when it detects an imbalanced load
- Lid-locking system prevents centrifuge from opening during operation (FC5513R)
Other Standard Features and Equipment
Ten acceleration and ten deceleration rates, pre-selection of running time from 10 sec to 99 hr 59 min or continuous, audible signal at the end of each run with melody options, quick spin for short runs
Compliance
- Product Safety: IEC/EN 61010-1; IEC/EN 61010-2-020
- Electromagnetic Compatibility: IEC/EN 61326-1 Class B, Basic environments
- Compliance Mark: CE
Weight:
30.00 lb
|
|
Other Ohaus Frontier 5000 Micro Centrifuges
|
Specifications
Model |
FC5513 (120V) |
FC5513R (120V) |
FC5515 (120V) |
FC5515R (120V) |
Price |
|
|
|
|
Speed Range |
200 rpm – 13,500 rpm; 10 rpm/increments |
200 rpm – 14,500 rpm; 10 rpm/increments |
200 rpm - 15,200 rpm; 10 rpm/set |
200 rpm - 15,200 rpm; 10 rpm/set |
Maximum RCF |
17,317 x g; 10 x g/increments |
17,157 x g; 10 x g/increments |
21,953 x g; 10 x g/set |
21,953 x g; 10 x g/set |
Maximum Capacity (Rotor) |
24 x 1.5/2.0 ml |
44 x 1.5/2.0 ml; 12 x 5 ml |
Temperature Range |
Air cooled |
-4 oF to 104 oF, 33.8 oF/increments -20 oC to 40 oC, 1 oC/increments |
Air cooled |
-4 oF to 104 oF, 33.8 oF/increments -20 oC to 40 oC, 1 oC/increments |
Running Time |
Quick Spin, 10 sec to 99 hr 59 min 59 sec, or continuous |
10 sec to 99 hr 99 min 59 sec or continuous) |
Noise Level |
< 60 dB(A) |
< 56 + 2 dB(A) |
< 60 dB(A) |
< 57 + 2 dB(A) |
Acc/Dec Levels |
10/10 |
Call |
Allowable Density at Maximum Speed |
1.2 g/ml |
Call |
Allowable Kinetic Energy d |
2,129 Nm |
2,266 Nm |
Call |
AC Power |
120 V/50-60 Hz |
Voltage Fluctuation |
+ 10 % |
Current Consumption |
1.9 A |
2.3 A |
5.1 A |
Power Consumption |
170 W |
320 W |
280 W |
560 W |
ECM |
- |
- |
EN/IEC 61326-1 Class B emissions, Basic immunity FCC Class B emissions |
EN/IEC 61326-1 Class B emissions, Basic immunity FCC Class B emissions |
Dimensions (W x D x H) |
10.9 × 14.0 × 9.3 in 277 × 356 × 236 mm |
11.3 x 21.9 x 11.3 in 287 x 555 x 286 mm |
11.29 x 15.47 x 11.49 in 287 x 393 x 292 mm |
11.29 x 22.08 x 11.49 in 287 x 561 x 292 mm |
Net Weight (without rotor) |
27.8 lb / 12.6 kg |
73 lb / 33 kg |
38 lb / 17 kg |
77 lb / 35 kg |
Shipping Dimensions (W x D x H) |
14.6 × 18.5 × 13.4 in / 370 × 470 × 340 mm |
15.7 x 26 x 20.5 in / 400 x 660 x 520 mm |
15.74 x 21.45 x 16.14 in / 400 x 545 x 410 mm |
15.74 x 25.98 x 20.47 in / 400 x 660 x 520 mm |
Shipping Weight (without rotor) |
30.9 lb / 14 kg |
83.5 lb / 38 kg |
44 lb / 20 kg |
97 lb / 44 kg |
Model |
Description |
Max. Speed |
FC5513 |
FC5513R |
Max. RCF |
FC5513 |
FC5513R |
30472302 |
Rotor Angle 24 x 1.5/2.0 ml BIOSEALS V1 |
13,500 rpm |
13,000 rpm |
17,317 x g |
16,058 x g |
Accessories
Order No |
Description |
Vol./Tube |
Diameter |
Tube Type |
No.of Tubes/Rotor |
Without Adapter |
Rotor Angle 24 x 1.5/2.0 ml BIOSEALS V1 |
1.5/2.0 ml |
11 mm |
Microtube |
24 |
30130885 |
Adapter 1 x 0.5 ml D8 mm 6/pk |
0.5 ml |
8 mm |
Microtube |
24 |
30130884 |
Adapter 1 x 0.2/0.4 ml D6 mm 6/pk |
0.2/0.4 ml |
6 mm |
Microtube |
24 |
|
Model |
Description |
Max. Speed |
FC5513 |
FC5513R |
Max. RCF |
FC5513 |
FC5513R |
30472304 |
Rotor Hematocrit 24 x Capillaries V1 |
13,000 rpm |
- |
16,058 x g |
- |
Accessories
Order No |
Description |
Vol./Tube |
Diameter |
Tube Type |
No.of Tubes/Rotor |
Without Adapter |
Rotor Hematocrit 24 x Capillaries V1 |
- |
1.9 mm |
Capillaries |
24 |
|
Model |
Description |
Max. Speed |
FC5513 |
FC5513R |
Max. RCF |
FC5513 |
FC5513R |
30210898 |
Rotor Angle 24 x 2.0 ml Spin Column |
13,500 rpm |
- |
17,317 x g |
- |
Accessories
Order No |
Description |
Vol./Tube |
Diameter |
Tube Type |
No.of Tubes/Rotor |
Without Adapter |
Rotor Angle 24 x 2.0 ml Spin Column |
2 ml |
11 mm |
Spin Column |
24 |
Model |
Description |
Max. Speed |
FC5513 |
FC5513R |
Max. RCF |
FC5513 |
FC5513R |
83041006 |
Rotor Angle 18 x 1.5/2.0 ml Sealable |
- |
14,500 rpm |
- |
17,157 x g |
Accessories
Order No |
Description |
Vol./Tube |
Diameter |
Tube Type |
No.of Tubes/Rotor |
Without Adapter |
Rotor Angle 18 x 1.5/2.0 ml Sealable |
1.5/2.0 ml |
11 mm |
Microtube |
18 |
30130885 |
Adapter 1 x 0.5 ml D8 mm 6/pk |
0.5 ml |
8 mm |
Microtube |
18 |
30130884 |
Adapter 1 x 0.2/0.4 ml D6 mm 6/pk |
0.2/0.4 ml |
6 mm |
Microtube |
18 |
|
Model |
Description |
Max. Speed |
FC5513 |
FC5513R |
Max. RCF |
FC5513 |
FC5513R |
83041014 |
Rotor Angle 4 x 8-Place PCR Strip V1 |
13,500 rpm |
13,000 rpm |
14,669 x g |
13,602 x g |
Accessories
Order No |
Description |
Vol./Tube |
Diameter |
Tube Type |
No.of Tubes/Rotor |
Without Adapter |
Rotor Angle 4 x 8-Place PCR Strip V1 |
0.2 ml |
6 mm |
8-w PCR Strip |
32 |
|
|
|
|
* within the 48 continental US States
|
Optional Accessories
more info
|
Ohaus 30472304 Frontier Hematocrit 24xCapillaries V2 Rotor
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Maximum Capacity (Rotor) |
24 x Capillaries |
Maximum Relative Centrifuge Force (x g) |
16,058 g |
Net Weight |
0.14 kg (0.31 lb) |
Outer/Inner Radius (numeric) |
9.3 cm |
Rotor Style |
Angle |
Maximum Speed |
13,000 rpm |
Aerosol tight |
Not applicable |
Maximum loading weight |
4.8 g |
Acceleration Time(sec) |
20 / 156 |
Dimensions (ØDiameter) |
20.2 cm (7.95 in) |
Angle |
90° |
Tube diameter without adapter |
N/A |
Compatible Models |
FC5513 |
Deceleration Time (sec) |
22 / 160 |
Working Environment |
-4°F – 122°F, 95%RH, non-condensing Temperature: -20ºC – 50ºC, Humidity: <95% |
|
|
more info
|
Ohaus 30472302 Frontier Angle BIOSEALS Rotor - 24 x 1.5 / 2.0 ml V2
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Maximum Capacity (Rotor) |
24 x 1.5 / 2.0 ml |
Maximum Relative Centrifuge Force (x g) |
17,317 g |
Maximum Speed |
13,500 rpm |
Rotor Style |
Angle |
Aerosol tight |
N/A |
Tube diameter without adapter |
12 mm / 2.0 ml,1.5 ml |
Outer/Inner Radius |
8.5 cm |
Acceleration Time(sec) |
15 / 110 |
Angle |
45° |
Deceleration Time(sec) |
14 / 118 |
Working Environment |
Temperature: -20ºC – 50ºC, Humidity: < 95% (-4°F – 122°F, 95%RH, non-condensing) |
|
|
more info
|
Ohaus 30210898 Angle Rotor 24 x 2.0 ml Spin Column R-A24X2/13M
OHAUS ANGLE ROTOR – 24 × 2.0 ml SPIN COLUMN (R-A24x2/13M)
The OHAUS R-A24x2/13M is a high-speed angle rotor designed for use with Frontier™ 5000 Series Microcentrifuges. It accommodates 24 × 2.0 ml spin column tubes, making it ideal for DNA/RNA extraction and molecular biology workflows. With a durable aluminum build and rotor angle of 45°, it offers reliable performance at speeds up to 13,500 rpm and 17,317 × g.
- Holds up to 24 × 2.0 ml spin column tubes
- Rotor angle: 45° for efficient sedimentation
- Max speed: 13,500 rpm
- Max RCF: 17,317 × g
- Durable aluminum construction
- Compatible with Frontier FC5513, FC5515, and FC5515R centrifuges
|
|
more info
|
Ohaus 83041006 Rotor Angle 18 x 1.5 / 2.0 ml Sealable R-A18X2/14MS
OHAUS Angle Rotor - R-A18X2/14MS
The OHAUS R-A18X2/14MS is a fixed-angle rotor for Frontier microcentrifuges. It holds 18 tubes (1.5 ml or 2.0 ml) at a 45-degree angle, supports speeds up to 14,500 rpm, and delivers a max RCF of 17,157 g. Ideal for high-performance lab work.
- Holds 18 x 1.5 ml or 2.0 ml tubes
- Fixed 45-degree angle for efficient separation
- Max speed: 14,500 rpm
- Max RCF: 17,157 g
- Compatible with OHAUS Frontier FC5513R
- Constructed of durable aluminum
|
|
more info
|
Ohaus 83041014 Rotor Angle 4 x 8-w PCR Strip V1 R-A4XPCR/14M
OHAUS Frontier Angle Rotors – Combined Overview
This collection of OHAUS Frontier angle rotors serves specialized lab needs, from hematocrit analysis to PCR prep and high-volume separations. Each rotor is compatible with Frontier microcentrifuges and designed for specific tube types and workloads.
- Fixed-angle designs for efficient, reproducible centrifugation
- Durable aluminum construction
- Supports a variety of sample formats: capillary tubes, large tubes, sealable tubes, and PCR strips
|
|
|
|
|
|
|
×
|