AND Weighing MC-1104A Mass Comparator 1100 g x 0.1 mg |
|
| The MC-A and MC-M series mass comparators deliver significantly improved precision and stability over the previous generation, enabling reliable comparison of reference weights in calibration labs—whether in-house or service-based. Despite the performance upgrades, the series remain cost-effective, making high-end mass comparison accessible to a broader range of users more ... |
|
Laboratory Equipment >
Analytical Balances >
Mass Comparators
|
|
|
|
|
|
Features
The MC-A and MC-M series mass comparators deliver significantly improved precision and stability over the previous generation, enabling reliable comparison of reference weights in calibration labs—whether in-house or service-based. Despite the performance upgrades, the series remain cost-effective, making high-end mass comparison accessible to a broader range of users.
Smart tools for confident mass comparison
Auto-centering pan to ensure consistent accuracy
One of the challenges in high-precision mass comparison is eccentricity error caused by off-center loading, which can compromise repeatability and overall measurement accuracy. The optional auto-centering pan addresses this by automatically bringing the mass to the center of the balance. Its dome-shaped bottom rests on three ball-tipped supports, allowing smooth movement to correct eccentricity errors. If an automatic loading system is not used, A&D strongly recommends this option for manual loading
Stable weighing through control of external disturbances
Mass comparators, due to their extremely high sensitivity, are more susceptible to various external disturbances. To help the MC-A and MC-M series fully demonstrate their true capabilities, A&D also recommends the following optional accessories
- Remote controller (AD-8922A) - Operate the balance without direct contact, reducing vibration caused by manual handling.
- Tabletop breeze breaks (AD-1676 or AD-1672(A)*1) - Shield the balance from drafts and minor temperature changes caused by air conditioning or operator movement. Made of antistatic panels to minimize static effects.
Extra decimal place for system integration and fine control
The MC-A and MC-M series offer extended resolution not typically available in balances of similar capacity. This extra decimal place enables accurate tracking of small weight changes—even with heavy tare weights common in automated systems for precise dosing, blending, and other demanding processes.
Impact shock detection (ISD) for reliable automation - The ISD function detects impact loads on the weight sensor and displays their intensity in five levels (0–4). High-impact events (Levels 3 and 4) also trigger an audible alert and are logged for review, supporting system adjustments to prevent future errors and sensor damage.
Beyond their primary role as mass comparators
Extra decimal place for system integration and fine control The MC-A and MC-M series offer extended resolution not typically available in balances of similar capacity. This extra decimal place enables accurate tracking of small weight changes—even with heavy tare weights common in automated systems for precise dosing, blending, and other demanding processes.
Impact shock detection (ISD) for reliable automation The ISD function detects impact loads on the weight sensor and displays their intensity in five levels (0–4). High-impact events (Levels 3 and 4) also trigger an audible alert and are logged for review, supporting system adjustments to prevent future errors and sensor damage.
Weight:
10.00 lb
|
|
Other AND Weighing MC-A/MC-M Series Mass Comparators
|
Specifications
| Model |
MC-1104A |
MC-6203A |
MC-10203M |
MC-32002M |
| Price |
|
|
|
|
| Capacity x Readability |
1100 x 0.0001 g (0.1 mg) |
6200 x 0.001g (1 mg) |
10.2 kg x 0.001g (1 mg) |
32.2 kg x 0.1 g |
| Repeatability (standard deviation)*i |
0.00035 g |
0.0035 g (over 2000 g) 0.0015 g (up to 2000 g) |
0.05 g (over 20 kg) 0.015 g (up to 20 kg) |
| Linearity*i |
±0.003 g |
±0.03 g |
±0.2 g |
| Linearity*i |
±0.003 g |
±0.03 g |
±0.2 g |
| Sensitivity drift (10 to 30 °C/50 to 86 °F, when automatic self-sensitivity adjustment is OFF) |
±2 ppm/°C |
±3 ppm/°C |
| Accuracy immediately after internal sensitivity adjustment*ii) |
±0.0100 g |
±0.150 g |
±1.50 g |
| Operating environment |
5 to 40 °C (41 to 104 °F), 85 %RH or less (no condensation) |
| Display refresh rate |
5 times/sec, 10 times/sec or 20 times/sec |
| Units of measure*iii |
g (gram), kg (kilogram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), and a user-programmable unit |
| Standard communication interface |
RS-232C (D-Sub 9-pin), USB (mini B) |
| Weighing pan size |
128 × 128 mm |
165 × 165 mm |
270 × 210 mm |
| External dimensions |
259 (W) × 358 (D) × 332 (H) mm (with the large glass breeze break) |
300 (W) × 355 (D) × 111 (H) mm |
| Net weight |
Approx. 7 kg |
Approx. 9.3 kg |
| Dust and waterproof rating |
N/A |
IP65 |
| Power supply / consumption |
AC adapter / approx. 30 VA |
| Standard accessories |
Breeze break × 1*iv, Display cover × 1, AC adapter × 1, USB cable (1.8 m) × 1 |
*i Under good environmental conditions using the auto-centering pan, or with consistent positioning in automated systems.
*ii Under good environmental conditions using the internal weight. The mass of the internal weight may change over time or due to environmental factors.
*iii The kg unit is for the MC-M series only. One additional unit from tael (Singapore/HK jewelry/Taiwan), tola, or Newton can be added upon request.
*iv Large glass breeze break for the MC-A series, and simple, soft plastic breeze break for the MC-M series.
Options
For the MC-A series
- GXA-03*2 2nd RS-232C interface
- GXA-04*2 Comparator relay output/buzzer/ external key input interface
- GXA-06*2 Analog (0-1/0.2-1 V) output interface
- FXi-08*2 Ethernet (TCP/IP) interface
- GXA-09*2 *3 Built-in rechargeable battery
- GXA-10*4 Large glass breeze break
- GXA-12 Animal weighing pan
- GXA-17*2 Large glass breeze break with built-in fanless ionizer and external IR switch
- GXA-23-PRINT*2 External key input interface + AX-SW137-PRINT foot switch
- GXA-23-REZERO*2 External key input interface + AX-SW137-REZERO foot switch
- GXA-23-PLUG*2 External key input interface + AX-T-314A-S plug
- GXA-24A*2 USB host interface
- GXA-25*2 Fanless ionizer with Quick Ion® technology
- GXA-26* External IR switch
- GXA-27*2 Bluetooth® interface
*2 Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-17, GXA-23-PRINT /REZERO/PLUG, GXA-24A, GXA-25, GXA-26, or GXA-27 can be installed
*3 Factory-installed/dealer option
*4 Also provided as standard
For the MC-M series
- GXM-04*5*6 Comparator relay output/buzzer/RS-232C/external key input interface
- GXM-06*5*6 Analog (0-1/0.2-1 V) output/RS-232C interface
- GXM-08*5*6 Ethernet (TCP/IP) interface
- GXK-012 Animal weighing pan
- GXM-27*5 Bluetooth® interface
- *5 Only one of GXM-04, GXM-06, GXM-08, GXM-27, or the standard (RS-232C and USB) interfaces can be installed.
- *6 The MC-M series is not IP65 with GXM-04, GXM-06, or GXM-08.
Accessories
- AD-1603*7 Calibration masses
- AD-1682 Rechargeable battery unit
- AD-1683A*8 Static eliminator
- AD-1684A Electrostatic fieldmeter
- AD-1687 Weighing environment logger
- AD-1688 Weighing data logger
- AD-1689 Tweezers for calibration weight
- AD-8129TH Compact printer
- AD-8526 RS-232C/Ethernet (TCP/IP) converter
- AD-8541-PC Bluetooth® dongle for PC
- AD-8541-SCALE RS-232C/Bluetooth® converter
- AD-8920A Remote display
- AD-8922A Remote controller
- AX-073007197-S Display cover for the MC-M series (5 pcs)
- AX-GXA-31 Display cover for the MC-A series (5 pcs)
- AX-MC10K/30KPAN Auto-centering pan for the MC-M series
- AX-MC1104APAN Auto-centering pan for the MC-1104A
- AX-MC6203APAN Auto-centering pan for the MC-6203A
- AX-USB-9P RS-232C/USB converter with cable
*7 Available in weights from 1 mg to 20 kg, in OIML classes E2, F1, and F2
*8 For in-line use in automated systems, the AD-1683 (without A) is recommended.
|
|
|
* within the 48 continental US States
|
|
Optional Accessories
more info
|
AND Weighing GXA-17 Large Glass Breeze Break with built-in Fanless Ionizer Static Sliminator
AND Weighing GXA-17 Large Glass Breeze Break with built-in Fanless Ionizer Static Sliminator The fanless ionizer can neutralize even extremely fine powders without disturbance
|
|
more info
|
AND Weighing AD-8541-SCALE RS-232C to Bluetooth® Converter
AND Weighing AD-8541-SCALE RS-232C to Bluetooth® Converter
|
|
more info
|
AND Weighing GXA-27 Bluetooth Interface Factory Installed Only
AND Weighing GXA-27 Bluetooth Interface Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. GXA-27 is a Bluetooth communication option. By pairing specific product, PC, tablet or smartphone equipped with Bluetooth function, you can communicate with the balance. Dust and waterproof balances can communicate with Bluetooth device by using GXA-27 maintaining its performance.
|
|
more info
|
AND Weighing GXA-23-PRINT External key input interface with the AX-SW137-REZERO foot switch PRINT - Factory Installed Only
AND Weighing GXA-23-PRINT External key input interface with the AX-SW137-REZERO foot switch PRINT - Factory Installed Only
|
|
more info
|
AND Weighing AD-1684A Electrostatic Field Meter
The AD-1684A is an electrostatic fieldmeter designed for detecting the existence of static electricity, which is often the cause of inaccurate weighing.
The AD-1684A can be used for measuring the electrostatic charge of measured objects or on automated factory lines, and for confirming the effect of a static eliminator (e.g. the AD-1683).
- Compact and light body
- Large, easy-to-read LCD
- Amount of the electrostatic charge also displayed as a bar graph
- Hold function
- Possible to measure the ion balance of a static elimination device
|
|
more info
|
AND Weighing AD-8526-9:Ethernet Adapter D-Sub 9 with WinCT Plus
AND Weighing AD-8526-9:Ethernet Adapter D-Sub 9 with WinCT Plus
|
|
more info
|
AND Weighing AD-8541-PC Bluetooth Wireless Communication Interface for PC
The AD-8541-PC enables a PC (with communication software such as WinCT installed) to
wirelessly receive data from and send commands to the SJ-WP-BT series through its USB
port.*7
The commands available with the SJ-WP-BT series include read/set comparator
limit values as well as request data, zero, tare, clear tare, and switch the weighing unit so
that you can avoid troublesome key operation with the scale when confirming and/or
changing the comparator limit values.
*7 The driver software for the AD-8541-PC is automatically installed with Windows 8.1 or
later. If the driver cannot be installed, download it from the [Support] - [Software]
section of the A&D website (www.aandd.jp), where WinCT is also downloadable for free
|
|
more info
|
AND Weighing GXA-26 External IR switch Factory Installed Only
AND Weighing GXA-26 External IR switch Factory Installed Only Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. For touchless operation of print or re-zero (tare). Factory Installed Only
|
|
more info
|
AND Weighing GXA-25 External Fanless Ionizer Static Eliminator Factory Installed Only
AND Weighing GXA-25 External Fanless Ionizer Static Eliminator Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. Power is supplied from the balance. Activated for a set duration with an IR sensor. Factory Installed Only
|
|
more info
|
AND Weighing GXA-24 USB host interface Factory Installed Only
AND Weighing GXA-24 USB host interface Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. Accepts an off-the-shelf USB flash drive to save weighing results in CSV format.
|
|
more info
|
AND Weighing GXA-23-PLUG External Key Input Interface with the AX-T-314A-S Plug - Factory Installed Only
AND Weighing GXA-23-PLUG External Key Input Interface with the AX-T-314A-S Plug - Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. Factory Installed Only
|
|
more info
|
AND Weighing GXA-23-RZERO External key input interface with the AX-SW137-REZERO foot switch - Factory Installed Only
AND Weighing GXA-23-REZERO External key input interface with the AX-SW137-REZERO foot switch - Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. Factory Installed Only
|
|
more info
|
AND AD-1682 Rechargeable Battery Pack
Rechargeable Battery Pack for AND Weighing balances
|
|
more info
|
AND Weighing GXA-12 Animal Weighing Pan for Apollo Series Models of 320g Capacity or Higher
AND Weighing GXA-12 Animal Weighing Pan for Apollo Series Models of 320g Capacity or Higher
|
|
more info
|
AND Weighing GXA-10 Large Glass Breeze Break
AND Weighing GXA-10 Large Glass Breeze Break The glass panes disappear into the back when opening the door, requiring no extra space at the rear of the balance. Easily attachable/detachable
|
|
more info
|
AND Weighing GXA-06 Analog Output (Cable: MiniDIN 4 pin Male to Loose end) Factory Installed Only
AND Weighing GXA-06 Comparator Output (Cable: MiniDIN 8 pin Male to Loose end) Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed.
|
|
more info
|
AND Weighing GXA-03 2nd RS-232C interface Factory Installed Only
AND Weighing GXA-03 2nd RS-232C interface
Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed.
|
|
more info
|
AND Weighing GXA-04 Comparator Output (Cable: MiniDIN 8 pin Male to Loose end) Factory Installed Only
AND Weighing GXA-04 Comparator Output (Cable: MiniDIN 8 pin Male to Loose end)
|
|
more info
|
AND Weighing AD-1689 Calibration weight tweezers, pack of 5
| With a length of 210 mm, the tweezers allow a weight to be placed in a weighing pan without having to put a hand inside the chamber. This prevents convection flow that is normally attributed to heat coming from the hand. |
| Each tweezer is made from austenitic stainless steel (SUS304), therefore heat from the hand is unlikely to be transmitted to the weight via the tweezers. This is especially effective for the precise measurements required of analytical balances.
|
| Tips of the tweezers are covered in resin to prevent the weight from slipping. The hilt is also covered with resin for easy gripping. |
|
|
more info
|
AND Weighing- AD-1688 -Weighing Data Logger
| AD-1688 |
Specifications |
| Application devices |
Balances and scales manufactured by A&D with an RS-232C connector |
| Memory size |
Approx. 5,000 data sets in the standard format (15 characters in 1 data set) can be stored |
| Clock error |
±1 minute / month |
| Applicable OS |
Windows 2000 / XP / Vista |
| Dedicated power supply |
Not required. Power is supplied by the weighing instrument or PC. |
| Operating environment |
50°F - 86°F (5°C - 40°C ), 85%RH or less (no condensation) |
| Dimensions |
Approx. 2.1 oz (60 g) |
| Weight |
Approx. 2.1 oz (60 g) |
|
|
more info
|
AND Weighing -AD-1687 - Weighing Environment Logger
| Data capacity |
Maximum 10,000 sets (including date and time) |
| Interval time |
1, 2, 5, 10, 15, 20, 30 seconds, 1, 2, 5, 10, 15, 20, 30, 60 minutes |
| Power supply |
Two LR6 (AA) batteries, RS-232C, or USB |
| Battery life |
Approx. 6 months (with measurement interval at 1 minute, alkaline batteries) |
| Clock accuracy |
Maximum ±1 minute/month |
| Compatible operating systems |
Windows 2000 / XP / Vista / 7 (32 / 64 bit) |
| Operating environment |
0 to 60 °C / 32 to 140 °F, 85% RH or less (no condensation) |
| Dimensions |
127 (W) × 90 (H) × 36 (D) mm (including the protective cover) |
| Weight |
Approx. 275 g (including batteries and the protective cover) |
| Standard accessories |
Three RS-232C cables for weighing instruments (9-pin D-Sub, 25-pin D-Sub, and 7-pin DIN, 1 m), USB cable (1 m), Two LR6 (AA) batteries (for operation check), Protective cover, Instruction manual |
| Sensor |
Resolution |
Measurement range |
Accuracy |
| Temperature |
0.1 °C ,0.1 °F |
0.1 °F 0 to 60 °C ,32 to 140 °F |
32 to 140 °F ±0.5 °C (20 to 30 °C),±0.9 °F (68 to 86 °F) |
| Relative humidity |
0.1% RH |
0 to 100% |
<±3% (20 to 80%)/td>
|
| Barometric pressure |
0.1 hPa |
500 to 1100 hPa |
hPa ±3 hPa (0 to 60 °C) |
| Vibration |
1 mG |
0 to 2000 mG |
±20%, static acceleration |
|
|
more info
|
AND Weighing FXi-08 Ethernet interface with WinCT-Plus software for FXi--Series
AND Weighing FXi-08 Ethernet interface with WinCT-Plus software for FXi--Series
FXi-02, FXi-08 and FXi-09 cannot be used at the same time.
(Not IP65 compliant when used with FX-iWP and FZ-iWP)
|
|
more info
|
AND AD-8922A Remote Controller
Remote Controller for AND Weighing balances
Displays weighing data Remotely controls a weighing instrument with key operations (no access to the internal settings) Outputs weighing data to another external device such as a PC or printer via the RS-232C connection Optional BCD, comparator, and analog outputs available Can be panel-mounted
|
|
more info
|
AND AD-8920A Universal Remote Display
Universal Remote Display for AND Weighing balances
Connects to A&D’s balances and scales using either RS-232C or current loop
Includes an AC adapter and a communication cable that matches your instrument
Recognizes the balance/scale baud setting automatically
Large and bright VFD display
|
|
|
|
|
|
|
|
|