RADWAG WAY 500.4Y.KO Class-leading manual mass comparator 520 g x 0.01 mg |
|
Mass comparator WAY 4Y.KO series similarly to other models, comprises two components. One of them holds the electronic module, and the other precise mechanical measuring system. 520 g x 0.01 mg more ... |
Laboratory Equipment >
Analytical Balances >
Mass Comparators
|
Specifications Chart
|
Have Questions? Our Staff will be glad to help |
Capacity x Readability
520 kgx 0.01 mg
Pan Size
50 mm (Diameter)
|
|
|
|
|
|
|
Features
Mass comparator WAY 4Y.KO series similarly to other models, comprises two components. One of them holds the electronic module, and the other precise mechanical measuring system.
The WAY 4Y.KO series comes standard with an aesthetic, large weighing chamber with glass anti-draft shield. All elements of the weighing chamber are manufactured from glass or metal to minimize the influence of electrostatic charges on weighing result. Mass comparator WAY 4Y.KO series features an intuitive menu supporting a user while operating the instrument.
- Effective and Excellent Measurement The WAY 4Y.KO series stands for a class-leading automatic mass comparator. The series enables comparison of weights ranging from 1 mg to 5 kg for class E1.
- Excellent Measurement Repeatability The WAY 4Y.KO mass comparator is equipped with a spacious weighing chamber made of glass and a ring-shaped draft shield. Mass comparators of higher accuracy feature an internal glass anti-draft chamber minimizing the influence of ambient conditions on measurement result.
- Design and Functionality The ring-shaped draft shield, apart from protecting the load against air drafts, prevents potential shocks that may occur during weighing pan loading. The weighing pan made of top-class non-magnetic stainless steel features marking facilitating centric loading of weights Anti-draft chamber made of glass reduces the influence of air drafts on comparison process. With use of conductive coating, the glass enables discharge of electrostatic charges.
- Dedicated Software Specially designed RMCS computer software enables comprehensive realisation of calibration procedures in laboratory. The system manages the whole calibration process, starting from the moment the order is placed, through procedure performance, to the moment of issuing the calibration certificate.
Functions
- Mass comparator
- Ambient conditions measurement
- Proximity sensors
- Replaceable units
- Multilingual menu
Anti-draft chamber made of glass reduces the influence of air drafts on comparison procedure
External supplementary loads for comparison of non-standard weights
|
|
Specifications
Model |
WAY 100.4Y.KO |
WAY 500.4Y.KO |
WAY 1.4Y.KO |
WAY 2.4Y.KO |
WAY 5.4Y.KO |
Capacity x Readability |
110 g x 0.001 mg |
520 g x 0.01 mg |
1.02 kg x 0.01 mg |
2.3 kg x 0.1 mg |
5.05 kg kg x 0.1 mg |
Repeatability absolute * |
0.005 mg (100 g) |
0.04 mg (500 g) |
0.05 mg (1000 g) |
0.2 mg (2000 g) |
0.3 mg (5000 g) |
Repeatability nominal load * |
0.0035 mg (100 g) |
0.025 mg (500 g) |
0.035 mg (1000 g) |
0.1 mg (2000 g) |
0.2 mg (5000 g) |
Repeatability low load * |
0.0025 mg (5 g) |
0.015 mg (10 g) |
0.025 mg (10 g) |
0.08 mg (100 g) |
0.15 mg (100 g) |
Repeatability low load * |
0.003 mg (100 g) |
0.02 mg (500 g) |
0.03 mg (1000 g) |
0.09 mg (2000 g) |
0.15 mg (5000 g) |
Stabilization time |
30 s |
30 s |
20 s |
20 s |
20 s |
Adjustment |
External Calibration |
External Calibration |
External Calibration |
External Calibration |
External Calibration |
Electric compensation range |
– 1 g ÷ 10 g |
– 10 g ÷ 20 g |
– 10 g ÷ 20 g |
–50 g ÷ 300 g |
–10 g ÷ 50 g |
Internal supplementary weights |
semi-automatic |
semi-automatic |
semi-automatic |
semi-automatic |
semi-automatic |
External supplementary weights |
10 g |
30 g, 2 x 10 g |
50 g, 30 g, 2 x 10 g |
2 x 100 g |
500 g, 300 g, 100 g, 50 g, 30 g, 2 x 10g |
Eccentricity (for test weight) |
1 d / 1 mm |
1 d / 1 mm |
1 d / 1 mm |
1 d / 1 mm |
1 d / 1 mm |
OIML calibration range E1 |
5 g ÷ 100 g |
200 g ÷ 500 g |
500 g ÷ 1 kg |
1 kg ÷ 2 kg |
2 kg ÷ 5 kg |
OIML calibration range E2 |
100 mg ÷ 100 g |
10 g ÷ 500 g |
100 g ÷ 1 kg |
500 g ÷ 2 kg |
500 g ÷ 5 kg |
OIML calibration range F1 |
1 mg ÷ 100 g |
1 g ÷ 500 g |
10 g ÷ 1 kg |
100 g ÷ 2 kg |
100 g ÷ 5 kg |
OIML calibration range F2 |
1 mg ÷ 100 g |
1 g ÷ 500 g |
1 g ÷ 1 kg |
10 g ÷ 2 kg |
10 g ÷ 5 kg |
OIML calibration range M1 |
1 mg ÷ 100 g |
1 g ÷ 500 g |
1 g ÷ 1 kg |
1 g ÷ 2 kg |
1 g ÷ 5 kg |
OIML calibration range M2 |
1 mg ÷ 100 g |
1 g ÷ 500 g |
1 g ÷ 1 kg |
1 g ÷ 2 kg |
1 g ÷ 5 kg |
Display |
5.7" color resistive touch screen |
Keypad |
8 keys |
Ingress protection - indicator |
IP 43 |
Touch-free operation |
2 programmable sensors |
USB-A |
2 |
Ethernet |
10 / 100 Mbit |
RS-232 |
2 |
Wi-Fi |
802.11 b/g/n |
IN/OUT |
4 x IN, 4 x OUT |
Power supply |
110 ÷ 230 V AC / 50 ÷ 60 Hz |
Operating temperature |
+15 ÷ +30 °C |
Operating temperature change rate |
± 0.5 °C / 12 h (± 0.3 °C / 4 h) |
Relative humidity variations |
± 3% / 4 h |
Relative humidity*** |
40 ÷ 60% |
Transport and storage temperature |
–20 ÷ +50 °C |
Weighing pan dimensions |
ø 30 mm |
ø 50 mm |
ø 60 mm |
ø 70 mm |
ø 90 mm |
Mass comparator dimensions** |
385 x 217 x 525 mm |
Indicator dimensions** |
206 x 140 x 71 mm |
Anti-draft chamber dimensions** |
560 x 565 x340 mm |
Mass comparator net weight |
21.5 kg |
22.5 kg |
23 kg |
24.5 kg |
24 kg |
Mass comparator gross weight |
31.5 kg |
33.5 kg |
33 kg |
34.5 kg |
34 kg |
Anti-draft chamber net weight |
14 kg |
14 kg |
14 kg |
14 kg |
14 kg |
Anti-draft chamber gross weight |
24 kg |
24 kg |
24 kg |
24 kg |
24 kg |
Mass comparator packaging dimensions** |
860 x 750 x 570 mm |
Anti-draft chamber packaging dimensions** |
860 x 830 x 840 mm |
* repeatability is expressed as a standard deviation determined for 6 ABBA cycles
** dimensions: length x width x depth
*** non-condensing conditions
Wi-Fi ® is a registered trademark of Wi-Fi Alliance.
Accessories - Call for more info
Weighing Tables granite anti-vibration table |
Ambient Conditions THB-S or THB-P sensor |
Peripheral Devices Epson dot matrix printer barcode scanner |
Cables, Converters RS-232 – P0108 computer cable RS-232 – P0167 computer cable RS-232 – P0151 Epson printer cable |
Electrical Accessories power supply with ZR–02 battery |
Dedicated Software (not included) - Call for more info
RMCS System
- performance of calibration procedures in a laboratory from the moment the order is placed, to the moment of issuing a calibration certificate
- compatible with THB sensors enabling recording ambient conditions
- export of report results to various files
- archiving calibration protocols, orders, certificates and ambient conditions
R-LAB
- collecting measurements
- carrying out statistical analysis of measurements
- customized graphs and reports
Parameters Editor
- remote change of parameters
- remote on-line preview of the display
- displaying current mass indication
- software update
- file loading, editing and saving parameters to a file
- import and export of parameters
- interfaces: RS232, Ethernet and Wireless Connection
- quick and easy edition of balance parameters using computer ways of initializing the process of acquiring data from the weighing instrument and sending it to a computer
- readout of characters transmitted via RS 232 to a computer
RADWAG Remote Desktop
- remote control of the mass comparator using computer, telephone or tablet
- sending text messages
- version for Windows 10 and Android systems
|
|
|
* within the 48 continental US States
|
Optional Accessories
more info
|
RADWAG RMCS PC software for mass metrology
View Data Sheet (PDF)
More about the/RMCS
RMCS system, designed by RADWAG, is dedicated to management of calibrating and testing procedures in a laboratory from the moment of accepting an order, through its progress and until issuing a calibration certificate. The software manages the complete calibrating and testing process.
The operation of mass comparators in connection with the software for network management of calibration process provides improved efficiency, reliable measurement results and complete documentation from calibration process, together with lower labour costs.
The system enables initiating the calibration procedure by ordering a task to a mass comparator, and autonomous executing calibration process on a mass comparator. In both cases, data is transferred to the software for the purpose of registering, controlling and finally issuing a calibration certificate.
Mass comparators linked in the RMCS system autonomously cooperate with THB ambient conditions monitors enabling recording major ambient factors like temperature, humidity and atmospheric pressure throughout the control process. The modules are detachable from the mass comparators for calibration and adjustment of their sensors.
Data on current ambient conditions is displayed in real time on mass comparator’s display. The data is also sent do RMCS software for control and archiving purposes.
System modules:
Ambient conditions monitoring module:
- Installed and in direct cooperation with a mass comparator;
- Enabling recording ambient conditions (temperature, humidity, atmospheric pressure) and calculating air density;
- Continuous monitoring of ambient conditions in direct vicinity of a mass comparator and its weighing chamber;
- Graphic presentation of ambient conditions on mass comparator’s display.
Weighing module:
- Automatic and manual mass comparators used as components of the RMCS system;
- Access and management of databases on: standards, test objects, from the level of RMCS software;
- Execution of calibration tasks ordered in the RMCS software;
- Self test procedure determining mass comparator’s repeatability parameter;
- Transfer of measurement results to the software memory.
Calculating and data storage module:
- Sending tasks to mass comparators;
- Downloading data on mass and ambient conditions from mass comparators;
- Operation on databases of clients / tasks / standards;
- Monitoring of future calibration dates;
- Database of accomplished calibrations, printouts and saved documentation.
Software functions:
RMCS functionality:
- Complete management of a metrological laboratory calibrating mass standards and weights with application of Y series of RADWAG mass comparators;
- Calibration using ABBA and ABA methods;
- Application of MS SQL database for network supervision of multiple computer stands;
- Complete management of calibration orders;
- Extended database of mass standards and test objects;
- Extended database of clients, operators and users;
- Database of manual and automatic mass comparators;
- Database of calibration orders;
- Managing pending tasks based on issued calibration orders;
- Planning tasks and orders execution;
- Weight checking procedure without an order – Quick Check option;
- Manual or automatic calibration of test objects;
- Cooperation with RADWAG automatic mass comparators;
- Bilateral data synchronization with RADWAG mass comparators;
- Reporting from calibration process;
- Issuing calibration certificates according to pre-defined template;
- Exporting report results to various file formats: PDF, MS Word, Excel;
- Record of events;
- Register of orders and calibration certificates;
- Saving copies of all calibration protocols, orders, calibration certificates and records of ambient conditions;